Kaspersky SD-WAN
Contents
Contents
Shared storage requirements
Kaspersky SD-WAN uses shared storage (hereinafter also referred to as storage) to ensure fault tolerance. This storage contains the following directories with data that the orchestrator needs:
- backups — backup copies of VNF and PNF configurations
- firmware — CPE device firmware
- images — VNF images
- vnf_configs — files that can be used by scripts when configuring VNFs
- vnf_descriptions — VNF descriptors
We recommend using your own shared storage. The requirements for deploying the shared storage are as follows:
- Support for simultaneous read and write from multiple hosts.
- The recommended size depends on the size of the files being stored, but at least 40 GB of available protected space that supports further expansion.
- Bandwidth of the communication channel between the storage and the orchestrator must be at least 1 Gbps; 10-Gigabit Ethernet or 8-Gigabit FC (Fiber Channel) is recommended.
- The supported IOPS (input/output operations per second) value must be at least 250, at least 400 IOPS is recommended.
- Storage type:
- NFS
- iSCSI
- FC
- CephFS
- The storage must be mounted.
- Must stay available if the host restarts.